BD Alaris pump module administration sets 71 rows Alaris Pump Module Set 150mL Burette SmartSite Smallbore Tubing Segments Low Sorbing PE Lined Segments 0.2 Micron Filter 1.72 sq in Low Protein Binding 2 Roller 2 Pinch Clamp s 1 SmartSite Y site s 6 below pumping Bd DA 10 PA 50 MOZ Rank 61
Alaris Pump Module SmartSite Low Sorbing Infusion Set 0.2 Micron Low Protein Binding Filter 1 Needle Free Valve 6 From 2 Piece Male Luer Lock The BD Alaris Pump module is designed for the delivery of fluids medications blood and blood products using continuous or intermittent delivery for adult paediatric or neonatal patients.
Alaris GW Volumetric Pump 2/77 1000SM00006 Issue 4 Switches the pump between Primary and Secondary infusion modes if enabled Ensure that the tubing is inserted completely into the pumping channel avoiding any slack Position the IV fluid container to avoid spillage onto the pump.
Address 1907 Keller Andrews Rd Sanford NC 27330 Phone 919.609.9975 Email info unitedinfusion
Needle Free Connectors Set Length 280 cm Priming Volume 25 ml Bore 3 mm 1 Spiked Drip Chamber s Vented/Unvented Drops per ml 20 Hydrophobic Air Inlet Filter with Cap 15 µm Drip Chamber Filter 1 SmartSite Valve Y Port.
May 28 2017 Alaris Medical 600 Avanos Medical 40 B Braun 1 500 Baxter 750 BD 2 800 Long sterile tubing and clamp to allow the control of the flow The tubing that connects the bag of fluid to the patient is known as the primary tubing When an additional IV is attached to this tubing this is a secondary IV.
Infusion Pump Training Policy Tip Sheets IV Supplies Ordering Data Set Change / Issues Request Form Directions for Use Manual Alaris Updates Alaris Dataset Upload Instructions Navigation.
Becton Dickinson 2260 0500McKesson Medical Surgical Shop Products IV Therapy IV Administration Sets Primary Administration Sets Low Sorbing
Feb 21 2013 6 insert tubing into pump alaris in this case and set primary to low rate and VTBI for ex rate 30 ml VTBI 300 7 ensure primary NS is flowing into patient 8 scan antibiotics in MAR 9 spike antibiotic secondary bag site scrub connector site
We carry all the in demand IV tubing sets from the industry’s most trusted names such as the Alaris pump tubing used with the Alaris System We can provide for the needs of any facility from nursing simulation labs to community hospitals Browse our inventory of PCA and IV tubing for Alaris pump systems below or request a quote for more
Feb 18 2020 In July 2019 BD updated recalls on the Alaris pumps and infusion sets following an initial recall on April 15 when BD notified clinicians that the manufacturing process of the pumps resulted in
Aug 18 2017 I.e Primary line is NSS running at 10mL/hr and secondary IVPB Flagyl running at a rate of 100mL/hr If there is left over flagyl it will still infuse to gravity but at a rate of 10mL as opposed to 100mL I always kink the tubing The Alaris tubing is not positive pressure.
When loading primary IV tubing into the BD alaris pump module select all that apply A open the module door B Hold the upper fitment above the fitment recess and lower it down into the recess C Be certain there are no twists in the tubing D Press the blue safety clamp into the recess
MedSystem III Primary Sets Manufacturer BD Administration sets for use with the MedSystem III infusion pump Sets contain an integrated mechanism to help prevent accidental free flow Not made with natural rubber latex Set configurations are available with SmartSite needle free valves and standard injection ports Specifications Latex Free.
Feb 16 2019 The Alaris pumps at my facility and everywhere use Primary tubing the piece that you actually clip into the air in line sensor it has a blue removable cover around the part that goes in the pump door and Secondary tubing which you screw on to a needleless connector above the pump .
After removing the primary tubing set from the package what is done next Spiking the large white tubing spike into the end of the IV fluid bag IV Push Medication With Alaris Tubing 6 terms timzachary PLUS Applying A Male Sterile Cap 7 terms timzachary PLUS OTHER SETS BY
Alaris CC Syringe Pump Alaris Enteral syringe pump Alaris GH syringe pump Alaris GP Volumetric Pump Alaris VP volumetric pump Alaris GW Volumetric Pump Alaris PK Syringe Pump Alaris TIVA Syringe Pump CME BodyGuard series Signature Edition Single Channel Infusion Pump Gemini Series volumetric
Alaris Pump Module set Non Vented Blood Set 180 Micron Filter Roller 2 Slide Clamp s 1 SmartSite needle free valve s 65 below pumping segment from 2 piece Male Luer Lock Not Made with DEHP 15 Drop L 121 in L 308 cm PV 33 mL Fluid Path Sterile With one of the largest catalogs of medical surgical and diagnostic supplies available
Alaris Pump Module set Check Valve Roller Slide Clamp s 3 SmartSite needle free valve s 6 74 90 1 above pumping segment and 2 below from 2 piece Male Luer Lock Not Made with DEHP 20 Drop L 126 in L 320 cm PV 26 mL Fluid Path Sterile.
Attaching the tubing 1 Remove the IV tubing from its package Pull the blue clip from the cassette then tear off the white paper strips 2 Holding the TPN bag remove the seal from the large middle port at the bottom of the bag Once the seal is removed do not touch or
Tubing Collar Lower Assembly 3 Cassette Holders Pump Latch Mechanism Drives the cassette piston to move fluid through the tubing Air in Line Sensor Detects bubbles of air during infusion Tubing Collar Recess Holds tubing collar in place Front Panel Instrument Keys Display Screen Softkey Pads Channel Indicator Lights Green Steady
Buy iv sets iv infusion sets and iv administration sets that delivery fluids and medication to a patients veins We also carry iv sets used to rehydrate dogs and cats who may be dehydrated Choose from 15 drops 10 drops and 60 drops per minute for infusion therapy.
An excellent option to consider is the Primary Infusion Set 20 Drops/mL Drip Rate 117 in 2 smart site Eligible for FREE or discounted ground shipping Medex SKU ALA 2420 0007 See all products from Alaris 179.95 retail 215.94.
Primary Administration Set Alaris Pump Module 20 Drops / mL Drip Rate 114 Inch Tubing 1 Port IV ADMIN SET .2MICRO DEHP FREE 20/CS CARFUS
The Alaris Pump Module is an infusion pump that delivers fluids such as nutrients blood and medications into a patient s body in controlled amounts The syringe holds the solution and the infusion tubing connects the syringe to the patient through intravenous or enteral access.
Medline IV Admin Sets with Needle Free Y Sites Manufacturer Medline These IV sets are designed for gravity use only IV tubing is not compatible with infusion pump administration systems Do not contain DEHP Specifications Adapter Type Luer Lock Male Luer Lock Latex Free.
Address 1907 Keller Andrews Rd Sanford NC 27330 Phone 919.609.9975 Email info unitedinfusion
The Baxter single set can be used both as gravity and in the Sigma Spectrum Infusion pump throughout multiple care areas The Single Set Technology can reduce the number of set ups and teardowns which can decrease the risk of touch contamination and has shown up to 53 cost savings in IV tubing sets and up to 30 reduction in IV tubing usage.
Primes the IV tubing with some of the heparin solution Scrubs the hub of the IV site to be used Attaches the tubing to the catheter hub Traces the tubing from the patient to its point of origin or vice versa Turns on the infusion pump and enter the ordered nomogram for
Jul 24 2019 This machine can be set based and have free flow protection featuring the Smart Smite needle free valves This system is designed for a bag bottle or syringe delivery This unit can support primary and secondary piggyback delivery Alaris 8100 Infusion Pump Specifications This unit is about 8.9″ tall and weighs about 2.5 pounds.
Aug 17 2015 Part of the secondary tubing will always be below the bag of primary fluid on account of where the upper Y site is My understanding is that once the fluid level from the secondary reaches the top level of the primary bag the primary will take over leaving whatever secondary meds left in the tubing to sit and very slowly drop as the primary